Dometic CCC2 error codes: E1, E2, E7 and more

Reviewed 1 primary sourceSee sources

On a Dometic CCC2 thermostat, E1 means communication has been lost with one or more system power module boards. It does not identify a failed part by itself. Match the controller below and note the zone before using the code table.

Dometic · RV thermostat · Comfort Control Center 2 (CCC2). Models: CCC2 3314080.000 (black), CCC2 3314080.015 (white).

This page uses Revision B of manual 3314149.018 for the two CCC2 controllers above. It does not cover every Dometic thermostat or appliance; E6 is not listed in this manual’s error table.[1]

How to read the code

Codes and what to do

CodeMeaningWhat to doWho fixes it
E1The CCC2 thermostat has lost communication with one power module board or with all of them. Loss to all boards shuts the system down; an individual loss identifies the affected zone, with additional lost zones flashing.Note the code and every flashing zone. Follow the basic power checks in the manual’s Service section; if it persists, contact a qualified service technician.[1]Technician
E2The indoor temperature sensor circuit is open or its reading is outside range. Heating and cooling are locked out; manual fan operation remains available.The manual gives no owner action.[1]Technician
E3The indoor temperature sensor is shorted. Heating and cooling are locked out; manual fan operation remains available.The manual gives no owner action.[1]Technician
E4The outdoor temperature sensor circuit is open or outside range on equipped models. Heat-pump operation is locked out; air conditioning, furnace, heat strip and fan operation can continue.The manual gives no owner action.[1]Technician
E5The freeze-sensor circuit is open or outside range. Air conditioning is locked out; heat pump, furnace, heat strip and fan operation can continue using the last temperature set-point.The manual gives no owner action.[1]Technician
E7All system power module boards have lost their 120 V AC supply. The system shuts down.Use the manual’s normal generator/shore-power and 120 V AC/12 V DC fuse or breaker checks. If the fault remains, contact a qualified service technician; do not work on wiring.[1]Technician
E8One zone is configured for both a heat pump and a heat strip. Heating by those modes and air conditioning are locked out in that zone.The manual gives no owner action.[1]Technician
E9One zone is configured for a dehumidifier together with a heat pump or heat strip. Heat-pump, heat-strip and air-conditioning operation is locked out in that zone.The manual gives no owner action.[1]Technician

When to call a technician

After the manual’s basic power checks, contact a qualified service center if the problem remains. Give the code, affected zones and equipment identification. The controller model is not the air conditioner’s model number.[1] Our mobile RV repair listings cover Colorado Springs and the Boise area so far.

Sources

Facts on this page are restated from the manufacturer documents below. Codes differ by model and spec letter, so check the manual for your exact unit. We have not tested these codes on equipment.

  1. Comfort Control Center 2 thermostat operating instructionsDometic Corporation · 3314149.018, Revision B, 08/16 · Cover: controller models; pp. 3–4: installer configuration; p. 8: zone selection; p. 18: LCD error codes; p. 19: system reset; p. 20: service checks · retrieved

Primary publishers: Dometic Corporation. Spotted an error? Email the address in the footer with the model and the document you are using.